STEEL TUBES categories
Structural hollow sections
We offer a wide range of structural solutions within the following parameters:
Structural hollow sections sizes
OUTER DIAMETER (OD) | 10.2 - 139.7 mm |
WALL THICKNESS (WT) | 0.5 - 16.0 mm |
. Tubes used in the construction business are delivered according to | |
EN 10210-2, DIN 2448, NFA 49-501, STN and ČSN 42 5715, 42 5716, | See tube sizes acc. to European standards . |
GOST 8732 | See tube sizes acc. to Russian standards |
Steel for structural hollow sections
EN 10210-1 | S235JRH, S275JOH, S355JOH, S275J2H, S355J2H, S275NH, S275NLH, S355NH, S355NLH, S420NLH, S460NH, S460NLH. Marking system for steel grades according to EN |
GOST 8731 | 09G2S, 10, 20, 35, 45 |
Length of the structural hollow sections
Length [m] | for sizes [mm] |
5 – 6 | OD < 60.3 |
5 – 6 or 10 – 14 | OD => 60.3 and WT < 7.1 |
5 – 6 | OD => 60.3 and WT => 7.1 |
Types of supplied length of tubes are: | (a) random length, |
(b) fixed length ± 500 mm, | |
(c) exact length – 0 + 15 mm. |
 
 
Structural hollow section ends
The ends are vertical to the longitudinal axis and are without burrs. | The tubes with deburred ends or ends customized for welding. |
Tube OD | 26.7 - 114.3 mm |
|
Tube WT | 3.2 - 12.5 mm | |
Tube lengths | 4 - 13 meters | |
Deburring angle, a | 30°+ 5 and 37°± 2.5 | |
Dimension, c | 1.6 ± 0.8 mm |
Marking of structural hollow sections and tube bundles
(a) without marking, | |
Packaging of the structural hollow sections
Structural hollow sections are supplied in packages with a circular or hexagonal outline with a weight of 300 to 3 500 kgStructural hollow section testing
Mandatory testing | cast analysis, |
tensile test, | |
notched impact strength test (for the J2 group grade), | |
visual inspection of the tubes surface. | |
Optional testing | selection according to standards, |
single part analysis, | |
notched impact strength test for the JR and JO group. |
Certified test reports for structural hollow sections
EN 10204 | 2.2 nonspecified testing (only mandatory tests), |
3.1 specific testing, | |
3.2 after agreement . | |
STN 42 0250, ČSN 42 0250, | |
DIN 50049, 2.2 or 3.1.B, C. |
Straightness of structural hollow sections
Allowed straightness is 0.002 multiple of the tube length, for 1 meter length the allowed straightness is 3 millimeters. |
Condition, delivery and surface of structural hollow sections
The tubes are hot rolled above the transformation temperature and they are not heat treated. The structure's condition corresponds to normalized annealing. |
Structural hollow sections surface protection
While ordering, it is necessary to agree upon the method and means of temporarily protecting the surface of the tubes during transportation and storiage. |
Related links
Zone for customer
Search